Passionetennis - Il portale del tennista
Vuoi reagire a questo messaggio? Crea un account in pochi click o accedi per continuare.

Passionetennis - Il portale del tennistaAccedi














descriptionCorde Volkl: performance database EmptyCorde Volkl: performance database

more_horiz
Dati rilevati da Tennis Warehouse University e ricalcolati per dimensione piatto: 98 e schema 16/19(Organix 10 325/295). Spero vi possa essere utile. Appena riesco riesco farò lo stesso per gli altri modelli.

StringDwell Time (ms)Tension Change (lbs)Stiffness (lb/in)DifferenzialeSpin potencial
V-Pro 1634,7641,63250,086,95.0
V-Pro 1834,8537,95228,493,14.9
Cyclone 1636,7939,31207,482,56.2
Cyclone 1736,8937,95201,961,15.8
V-Pro 1737,0837,76200,310,75.1
Cyclone 1837,1837,18194,790,07.1
Cyclone Tour 17 (1.25)37,8637,37193,15-0,56.1
V-Torque 1636,2135,43184,24-0,85.6
Power-Fiber II 1635,6327,79166,52-7,83.2
Power-Fiber II 1735,4327,30163,81-8,12.7
Power-Fiber II 1835,6326,91161,59-8,72.9

descriptionCorde Volkl: performance database EmptyRe: Corde Volkl: performance database

more_horiz
Sorry,ho dimenticato un dato importante. Dati riferiti a tensione di 23 Kg. e swing medio:

StringDwell Time (ms)Tension Change (lbs)Stiffness (lb/in)DifferenzialeEnergy     return           (%)Spin potencial
V-Pro 1634,7641,63250,086,987,05.0
V-Pro 1834,8537,95228,493,190,34.9
Cyclone 1636,7939,31207,482,586,36.2
Cyclone 1736,8937,95201,961,186,85.8
V-Pro 1737,0837,76200,310,787,25.1
Cyclone 1837,1837,18194,790,085,97.1
Cyclone Tour 17 (1.25)37,8637,37193,15-0,585,96.1
V-Torque 1636,2135,43184,24-0,888,35.6
Power-Fiber II 1635,6327,79166,52-7,891,13.2
Power-Fiber II 1735,4327,30163,81-8,188,52.7
Power-Fiber II 1835,6326,91161,59-8,794,72.9

descriptionCorde Volkl: performance database EmptyRe: Corde Volkl: performance database

more_horiz
Per dimensioni piatto 100'' e schema 16x18 (Organix 8/8G 300/315)

StringDwell   time   (ms)Tension    change   (lb)DiffernzialeStiffness    (lb/in)Energy     return     (%)
Cyclone 1636,138,52,5203,484,6
Cyclone 1736,237,21,0198,085,1
Cyclone 1836,536,50,0191,084,2
Cyclone Tour 17 (1.25)37,136,6-0,5189,484,2
Power-Fiber II 1634,927,2-7,7163,389,3
Power-Fiber II 1734,726,8-8,0160,686,8
Power-Fiber II 1834,926,4-8,5158,492,8
Synthetic Gut 1634,428,0-6,4168,788,6
Synthetic Gut 1734,927,0-8,0162,290,3
V-Pro 1634,140,86,7245,285,3
V-Pro 1736,437,00,7196,485,5
V-Pro 1834,237,23,0224,088,6
V-Torque 1635,534,7-0,8180,686,6

descriptionCorde Volkl: performance database EmptyRe: Corde Volkl: performance database

more_horiz
...ma che schifo ho fatto??? Suspect

descriptionCorde Volkl: performance database EmptyRe: Corde Volkl: performance database

more_horiz
StringDwell   time   (ms)Tension    change   (lb)DiffernzialeStiffness    (lb/in)Energy     return     (%)
Cyclone 1636,138,52,5203,484,6
Cyclone 1736,237,21,0198,085,1
Cyclone 1836,536,50,0191,084,2
Cyclone Tour 17 (1.25)37,136,6-0,5189,484,2
Power-Fiber II 1634,927,2-7,7163,389,3
Power-Fiber II 1734,726,8-8,0160,686,8
Power-Fiber II 1834,926,4-8,5158,492,8
Synthetic Gut 1634,428,0-6,4168,788,6
Synthetic Gut 1734,927,0-8,0162,290,3
V-Pro 1634,140,86,7245,285,3
V-Pro 1736,437,00,7196,485,5
V-Pro 1834,237,23,0224,088,6
V-Torque 1635,534,7-0,8180,686,6

descriptionCorde Volkl: performance database EmptyRe: Corde Volkl: performance database

more_horiz
Sono in attesa della mia Volkl V1 Classic - l'ho fatta incordare di default con Volkl Power Fiber II 55lb (24.9 Kgs).

Lascerò feedback una volta testata Smile
privacy_tip Permessi in questa sezione del forum:
Non puoi rispondere agli argomenti in questo forum.
power_settings_newAccedi per rispondere